TCCC
The Construction Contracts Co.
Subcontract Review
VIC
Trades / Electrical / Victoria

Electrical subcontracts in Victoria: what to check before you sign

In Victoria, a electrical subcontract is read alongside the Building and Construction Industry Security of Payment Act 2002 (VIC), which caps subcontract payment terms at 20 business days. The contract itself still decides the risks that cost electrical subcontractors most: completion defined as commissioning and certification; variations from late design and coordination; defects liability that restarts.

AI risk report, not legal advice. The scanner gives general information about the risks in a document. It is not a lawyer, does not know your circumstances, and can be wrong. For decisions with legal consequences, get advice from a construction lawyer.

Scan a VIC electrical subcontract free
Free · no account · confidential · about two minutes

Victoria rules that override your contract

Statute: Building and Construction Industry Security of Payment Act 2002 (VIC)

  • Payment terms for subcontractors are capped at 20 business days after the payment claim. A longer term in the contract doesn't change that.
  • If the builder disputes a payment claim, it has to answer with a payment schedule within 10 business days (or any shorter period in the contract).
  • The Act was substantially reformed with effect from 15 April 2026: the old excluded-amounts and claimable-variations regimes are abolished, so damages, time-related costs and disputed variations can now generally be included in a payment claim, and reference dates are abolished too.
  • Adjudication: through a private authorised nominating authority; the reforms are recent and practice under them is still settling.

Victoria payment law in full →

Where electrical subcontractors lose money

Completion defined as commissioning and certification

If practical completion for your package needs the whole building energised, tested and certified, your liquidated damages clock runs while you wait on the authority, the HV upgrade or another trade's equipment. Define your completion by your own scope.

Variations from late design and coordination

Electrical design moves with every architectural and services change. A short or absolute notice window on variations means the redesign you absorbed on site becomes free work. Check the notice period and whether a written direction is required before you start.

Defects liability that restarts

Fittings and equipment fail for reasons outside your workmanship. A defects liability period that restarts on every rectification can keep your retention locked up well beyond the usual 12 months.

Supply risk on long-lead equipment

Switchboards, generators and specialist fittings can have long lead times. If the contract puts all supply delay on you with no extension of time, a manufacturer's delay becomes your liquidated damages.

Three things to push for in your departures schedule

  • Completion of the electrical works defined by your scope, not whole-of-building commissioning
  • A notice period for variations of at least 5 business days, as a notice requirement rather than an absolute bar
  • Extension of time for supply delays outside your control, with the manufacturer's notice as evidence

The free scanner finds these clauses in your actual contract in about two minutes and writes the departures schedule for you.

What the Index says

Live figures from the Australian Subcontract Index, 90 real subcontracts. The Index holds only 8 electrical contracts so far, under the 10-contract threshold, so these are national figures across all trades. Nothing under 10 contracts is ever shown.

100%have time bars that kill the claim entirely (66 of 66, all trades)
97%let the builder set off without notice (75 of 77, all trades)
78%have liquidated damages with no cap (31 of 40, all trades)
25 daysmedian payment terms (n=75, all trades)
5%median retention (n=65, all trades)
5 daysmedian notice window for variations (n=60, all trades)
See the full live Index →

Electrical subcontracts in other states

QLD · NSW · WA · SA · TAS · ACT · NT

Payment claim deadline checker →·Free notice templates →

Electrical subcontracts in VIC: common questions

How long does a builder in VIC have to pay a electrical subcontractor?

No more than 20 business days after your payment claim, whatever the contract says. If the builder disputes the claim, it has 10 business days to answer with a payment schedule giving its reasons.

Can a builder hold an electrician's retention until the whole building is certified?

Only if the subcontract says so, which is why the release trigger matters. Market practice is half at practical completion of your works and half at the end of the defects period. A trigger tied to the head contract's completion or final certificate can hold your money for years.

Where do VIC electrical payment disputes go?

Authorised Nominating Authorities (list via the Building and Plumbing Commission, formerly the VBA). Timing: through a private authorised nominating authority; the reforms are recent and practice under them is still settling.

Is this legal advice?

No. It is general information about common subcontract risks and the state's payment law as recorded in our registry. Statutory details change; check the current Act, and take the scanner's report to a construction lawyer for decisions with legal consequences.

General information, not legal advice. Statutory details are taken from our state law registry and change over time; verify them against the current Building and Construction Industry Security of Payment Act 2002 (VIC) before relying on them. Built by Mat Kennedy, Founder, The Construction Contracts Co.